Skip to main content
Skip table of contents

Hold for PMC State

Use this command to pause execution until PMC enters the specified state.

Fieldbus Interface

PMC_HoldForPMCState

Inputs

Name

Data Type

Description

Execute

BOOL

Execution of the function block begins on a rising edge of this input.

State

USINT

PMC State Description. 0: Booting; 1: Inactive; 2: Activating; 5: Operation; 7: Deactivating; 8: Error Handling; 9: Error

PM_Controller

PMControllerType

Data structure that specifies which PMC to connect to. There should be only 1 instance of this variable for each connected PMC.

Outputs

Name

Data Type

Description

Done

BOOL

Execution successful. Function block is finished. (Note: Done will not become TRUE if Execute is already FALSE) 

Busy

BOOL

Function block is active and must continue to be called.

Error

BOOL

If there is an error in processing the command, then Error = TRUE, otherwise, FALSE.

Conditions

Operating Conditions

Preconditions

None

Postconditions

Resume code execution

Description

Use this command to pause execution until PMC enters the specified state.

 

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.