Use this command to pause execution until PMC enters the specified state.

Fieldbus Interface
PMC_HoldForPMCState
Inputs
Name | Data Type | Description |
---|
Execute | BOOL | Execution of the function block begins on a rising edge of this input. |
State | USINT | PMC State Description. 0: Booting; 1: Inactive; 2: Activating; 5: Operation; 7: Deactivating; 8: Error Handling; 9: Error |
PM_Controller | PMControllerType | Data structure that specifies which PMC to connect to. There should be only 1 instance of this variable for each connected PMC. |
Outputs
Name | Data Type | Description |
---|
Done | BOOL | Execution successful. Function block is finished. (Note: Done will not become TRUE if Execute is already FALSE) |
Busy | BOOL | Function block is active and must continue to be called. |
Error | BOOL | If there is an error in processing the command, then Error = TRUE, otherwise, FALSE. |
Conditions
Operating Conditions |
---|
Preconditions | None |
Postconditions | Resume code execution |
Description
Use this command to pause execution until PMC enters the specified state.