This command is used to get the mover label of an XBot.
Fieldbus Interface
PMC_MoverLabel_GetLabel
Inputs
|
Name
|
Data Type
|
Description
|
|
Execute
|
BOOL
|
Execution of the function block begins on a rising edge of this input.
|
|
XbotID
|
USINT
|
ID of the XBot. Real XBot IDs [1,78].
|
|
PM_Controller
|
PMControllerType
|
Data structure that specifies which PMC to connect to. There should be only 1 instance of this variable for each connected PMC.
|
Outputs
|
Name
|
Data Type
|
Description
|
|
Done
|
BOOL
|
Execution successful. Function block is finished. (Note: Done will not become TRUE if Execute is already FALSE)
|
|
Busy
|
BOOL
|
Function block is active and must continue to be called.
|
|
Aborted
|
BOOL
|
Command aborted by another command.
|
|
Error
|
BOOL
|
If there is an error in processing the command, then Error = TRUE, otherwise, FALSE.
|
|
ErrorID
|
UINT
|
0x0: All OK. Otherwise, please see Fieldbus Reply Codes.
|
|
MoverLabel
|
UINT
|
Mover label assigned to the XBot.
|
Conditions
|
Operating Conditions
|
|
Preconditions
|
None.
|
|
Postconditions
|
XBot’s mover label is provided in the output.
|
Description
This command is used to get the mover label of an XBot.