This command will obtain the system warning log.
Fieldbus Interface
PMC_GetWarningLog
Inputs
|
Name
|
Data Type
|
Description
|
|
Execute
|
BOOL
|
Execution of the function block begins on a rising edge of this input. |
|
Bytes
|
SINT[0..99999]
|
The byte array to store the full warning log.
|
|
PM_Controller
|
PMControllerType
|
Data structure that specifies which PMC to connect to. There should be only 1 instance of this variable for each connected PMC. |
Outputs
|
Name
|
Data Type
|
Description
|
|
Done
|
BOOL
|
Execution successful. Function block is finished. (Note: Done will not become TRUE if Execute is already FALSE) |
|
Busy
|
BOOL
|
Function block is active and must continue to be called. |
|
Aborted
|
BOOL
|
Command aborted by another command. |
|
Error
|
BOOL
|
If there is an error in processing the command, then Error = TRUE, otherwise, FALSE. |
|
ErrorID
|
UINT
|
0x0: All OK. Otherwise, please see Fieldbus Reply Codes. |
|
nBytes
|
DINT
|
Number of bytes for the warning log.
|
Conditions
|
Operating Conditions
|
|
Preconditions
|
None
|
|
Postconditions
|
The Warning Log is stored in "Bytes", the size of the Warning Log is stored in "nBytes"
|
Description
This command will obtain the system warning log.