Chiller Selection

There are many chillers on the market which are suitable for cooling various sized Flyway systems. The table below contains examples of some chillers that are readily available. It is up to the customer to decide which chiller is suitable for their specific application: 

Product

Cost [USD]*

Cooling Capacity [W]

Notes

Max Flyways**

Configuration

Vevor CW5200

~400

1400

Accuracy ±1 °C

20

5 branches of 4 in series

SMC – HRS012-A-20-T

~4000

1100

Temperature stability 0.1 °C

20

5 branches of 4 in series

Thermofisher TF-900

Request quote

900

Temperature stability 0.1 °C

16

4 branches of 4 in series

Pfannenberg CCE 6101

Request quote

1100

Accuracy ±2 °C

20

5 branches of 4 in series

  • Subject to change

** Max Flyway estimate is based on typical system loading of 50W per Flyway-mover pair, and chiller-specific considerations

Select a chiller based on analysis of cooling capacity, coolant temperature accuracy requirements, and budget.