This command is used to control the operation of a specific border.
Fieldbus Interface
PMC_BorderControl
Inputs
|
Name
|
Data Type
|
Description
|
|
Execute
|
BOOL
|
Execution of the function block begins on a rising edge of this input. |
|
BorderID
|
USINT
|
Border ID, valid range [1,12] |
|
Control
|
USINT
|
-
0: Close border
-
1: Open border
|
|
PM_Controller
|
PMControllerType
|
Data structure that specifies which PMC to connect to. There should be only 1 instance of this variable for each connected PMC. |
Outputs
|
Name
|
Data Type
|
Description
|
|
Done
|
BOOL
|
Execution successful. Function block is finished. (Note: Done will not become TRUE if Execute is already FALSE) |
|
Busy
|
BOOL
|
Function block is active and must continue to be called. |
|
Aborted
|
BOOL
|
Command aborted by another command. |
|
Error
|
BOOL
|
If there is an error in processing the command, then Error = TRUE, otherwise, FALSE. |
|
ErrorID
|
UINT
|
0x0: All OK. Otherwise, please see Fieldbus Reply Codes. |
Conditions
|
Operating Conditions
|
|
Preconditions
|
The border has been configured
|
|
Postconditions
|
The border operation is modified
|
Description
This command is used to control the operation of a specific border.
Changelog
PMC v117.26.74 (Fieldbus v6.03.055.00) - Command released in fieldbus libraries